Objective To determine the contents of 17 kinds of hydrolyzed amino acids in donkey-hide glue by HPLC with pre-column derivatization at the same time.Methods To extract amino acids by the method of hydrolysis in 6 mol/L HCl and use phenylisothiocyanate(PITC) as the derivating agent.The Hypersil BDS C18 column(200 mm×4.6 mm,5 μm) was used.Under the condition of gradient elution,the flow rate was 1.0 mL/min,the UV detection wavelength was 254 nm,and the column temperature was 30 ℃.Results 17 kinds of amino acids can be separated well in 60...